The sensor is designed to operate in indoor conditions for standard doorways that allows frequent ingress and egress. The sensor may be top-mounted on door frames that are up to 8ft (2.4m) wide and 12ft (3.6m) tall.
The sensor must be mounted directly on the doorframe on the inside of the space. In a retail environment, it must be visible from inside the store.
We strongly recommend the installation of the sensor on a door frame due to height, width and traffic requirements. Under exceptional circumstances, ceiling mounting is allowed using an optional ceiling mount adapter which can be supplied by Dor team.
Due to the nature of the thermal technology, accuracy degrades substantially when the sensor is further away from average human height.
We do not recommend installing sensors on doorways that are wider than 8ft. Installing multiple sensors on the same doorway may degrade the accuracy of foot traffic data.
Due to individuals entering or leaving an elevator in a dense group at the same time, the sensor's accuracy may suffer. Instead, we recommend that sensors are deployed in doorways leading to elevator banks where possible.